Description
Compact design and easy installation
– There are many communication options: PROBIBUS, DeviceNet, CANopen.
– Able to create high starting moments.
– FCC (Flux Current Control) control gives high drive quality even when there is a load change.
– Built-in cascading function for cascading system.
– The built-in Bypass function directs the motor directly into the grid under certain conditions.
Power saving function
– 4 intermittent frequency range to avoid resonance on motor or machine.
– Start sticking when the inverter is connected to the rotating motor.
– Integrating thermal protection for motors using PTC / KTY.
Detailed specifications
– Input voltage: 380-480 V, 3AC
– Output frequency: 0-650 Hz
– Digital input: 6 (PNP / NPN)
– Analog inputs: 2 (0-10 V, 0-20 mA, -10 to +10 V)
– Digital output: 3 (relay 30 V DC / 5 A, 250 V AC / 2 A)
– Analog output: 2 (0-20 mA)
– Specialized for pumps and fans
STT |
Wattage kW |
Electric |
Electric |
Size |
6SE6430-2UD27-5CA0 |
7,5 (10) |
16 |
19 |
245 x 185 x 195 |
6SE6430-2UD31-1CA0 |
11 (15) |
22,5 |
26 |
245 x 185 x 195 |
6SE6430-2UD31-5CA0 |
15 (20) |
30,5 |
32 |
245 x 185 x 195 |
6SE6430-2UD31-8DA0 |
18,5 (25) |
37,2 |
38 |
520 x 275 x 245 |
6SE6430-2UD32-2DA0 |
22 (30) |
43,3 |
45 |
520 x 275 x 245 |
6SE6430-2UD33-0DA0 |
30 (40) |
59,3 |
62 |
520 x 275 x 245 |
6SE6430-2UD33-7EA0 |
37 (50) |
71,7 |
75 |
650 x 275 x 245 |
6SE6430-2UD34-5EA0 |
45 (60) |
86,6 |
90 |
650 x 275 x 245 |
6SE6430-2UD35-5FA0 |
55 (75) |
103,6 |
110 |
850 x 350 x 320 |
6SE6430-2UD37-5FA0 |
75 (100) |
138,5 |
145 |
850 x 350 x 320 |
6SE6430-2UD38-8FA0 |
90 (120) |
168,5 |
178 |
850 x 350 x 320 |