SIEMENS inverter G120

SKU: 61-bien-tan-siemens-g120 Category:

Description

Siemens inverter products of the G120 series Siemens Sinamics G120 frequency inverter is the most powerful new type inverter in AC motor control current with the capacity of 0.37kW to 250kW suitable for all applications of stepless speed control of 3-phase AC motor from 3-phase mains 380VAC. G120 inverter modularized design, optimized in the selection of equipment to suit each application.

Main features of the siemens G120

– Modular design, depending on the application, select the appropriate equipment and the economical price..
– Wide capacity range, suitable for motor power spread..
– Cooling design on aluminum foil, reducing dust, increasing inverter life..
– The PM250 power module type has built-in regenerative braking function to return the braking energy to the power-saving source, without the need of additional braking module and braking resistor..
– The control module has many options with many common In Out or networked control applications.
– Moment output is stable, very well served with lifting type such as crane, elevator.

SIEMENS G120 inverter has the following code

PART NUMBER

 

DESCRIPTION

 

6SL3244-0BA20-1BA0

SINAMICS G120ı
CONTROL UNIT CU240Sı
S-TYPE STANDARDı
RS485-INTERFACE, USS-PROTOCOLı
9 DI, 3 DO, 2 AI, 2 AOı
PTC/KTY INTERFACEı
EM-BRAKE RELAY, MMC INTERFACEı
ENCODER INTERFACEı
PROTECTION IP20ı
AMBIENT TEMP -10 TO +50 DEG Cı
WITHOUT POWER MODULE AND BOP

6SL3244-0BA20-1PA0

SINAMICS G120ı
CONTROL UNIT CU240S DPı
S-TYPE STANDARDı
PROFIBUS DPı
9 DI, 3 DO, 2 AI, 2 AOı
PTC/KTY INTERFACEı
EM-BRAKE RELAY, MMC INTERFACEı
ENCODER INTERFACEı
PROTECTION IP20ı
AMBIENT TEMP -10 TO +50 DEG Cı
WITHOUT POWER MODULE AND BOP

6SL3244-0BA20-1FA0

SINAMICS G120ı
CONTROL UNIT CU240S PNı
S-TYPE STANDARDı
PROFINETı
9 DI, 4 DO, 2 AI, 2 AOı
PTC/KTY INTERFACEı
EM-BRAKE RELAY, MMC INTERFACEı
ENCODER INTERFACEı
PROTECTION IP20ı
AMBIENT TEMP -10 TO +50 DEG Cı
WITHOUT POWER MODULE AND BOP

6SL3244-0BA21-1PA0

SINAMICS G120ı
CONTROL UNIT CU240S DP-Fı
S-TYPE SAFETY INTEGRATEDı
PROFIBUS DPı
8 DI, 3 DO, 2 AI, 2 AOı
PTC/KTY INTERFACEı
EM-BRAKE RELAY, MMC INTERFACEı
ENCODER INTERFACEı
PROTECTION IP20ı
AMBIENT TEMP 0 TO +45 DEG Cı
WITHOUT POWER MODULE AND BOP

6SL3224-0BE13-7UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 0,37KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
173 X 73 X 145 (HXWXD), FSAı
PROTECTION IP20ı

6SL3224-0BE15-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 0,55KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
173 X 73 X 145 (HXWXD), FSAı
PROTECTION IP20ı

6SL3224-0BE17-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 0,75KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
173 X 73 X 145 (HXWXD), FSAı
PROTECTION IP20ı

6SL3224-0BE21-1UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 1,1KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
173 X 73 X 145 (HXWXD), FSAı
PROTECTION IP20ı

6SL3224-0BE21-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 1,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
173 X 73 X 145 (HXWXD), FSAı
PROTECTION IP20ı

6SL3224-0BE22-2UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 2,2KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION IP20ı

6SL3224-0BE23-0UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 3,0KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION IP20ı

6SL3224-0BE24-0UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 4,0KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION IP20ı

6SL3224-0BE25-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 5,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 7,5KWı
FOR 150% 3S,110% 57S,1

6SL3224-0BE27-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 7,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 11KWı
FOR 150% 3S,110% 57S,10

6SL3224-0BE31-1UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 11KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 15KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE31-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 15KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 18,5KWı
FOR 150% 3S,110% 57S,1

6SL3224-0BE31-8UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 18,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 22KWı
FOR 150% 3S,110% 57S,1

6SL3224-0BE32-2UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 22KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 30KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE33-0UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 30KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 37KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE33-7UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 37KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 45KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE34-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 45KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 55KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE35-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 55KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 75KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE37-5UA0

SINAMICS G120ı
POWER MODULE PM240ı
WITHOUT FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 75KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 90KWı
FOR 150% 3S,110% 57S,100

6SL3224-0BE22-2AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 2,2KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION

6SL3224-0BE23-0AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 3,0KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION

6SL3224-0BE24-0AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 4,0KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
270 X 153 X 165 (HXWXD), FSBı
PROTECTION

6SL3224-0BE25-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 5,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 7,5KWı
FOR 150% 3

6SL3224-0BE27-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 7,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 11KWı
FOR 150% 3S

6SL3224-0BE31-1AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 11KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 15KWı
FOR 150% 3S,

6SL3224-0BE31-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 15KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 18,5KWı
FOR 150% 3

6SL3224-0BE31-8AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 18,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 22KWı
FOR 150% 3

6SL3224-0BE32-2AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 22KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 30KWı
FOR 150% 3S,

6SL3224-0BE33-0AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 30KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 37KWı
FOR 150% 3S,

6SL3224-0BE33-7AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 37KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 45KWı
FOR 150% 3S,

6SL3224-0BE34-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 45KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 55KWı
FOR 150% 3S,

6SL3224-0BE35-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 55KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 75KWı
FOR 150% 3S,

6SL3224-0BE37-5AA0

SINAMICS G120ı
POWER MODULE PM240ı
WITH BUILT IN CL. A FILTERı
WITH BULT IN BRAKING CHOPPERı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 75KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 90KWı
FOR 150% 3S,

6SL3225-0BE25-5AA1

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 5,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 7,5KWı
FOR 150% 3S

6SL3225-0BE27-5AA1

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 7,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 11KWı
FOR 150% 3S,

6SL3225-0BE31-1AA1

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 11KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 15KWı
FOR 150% 3S,1

6SL3225-0BE31-5AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 15KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 18,5KWı
FOR 150% 3S

6SL3225-0BE31-8AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 18,5KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 22KWı
FOR 150% 3S

6SL3225-0BE32-2AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 22KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 30KWı
FOR 150% 3S,1

6SL3225-0BE33-0AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 30KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 37KWı
FOR 150% 3S,1

6SL3225-0BE33-7AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 37KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 45KWı
FOR 150% 3S,1

6SL3225-0BE34-5AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 45KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 55KWı
FOR 150% 3S,1

6SL3225-0BE35-5AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 55KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 75KWı
FOR 150% 3S,1

6SL3225-0BE37-5AA0

SINAMICS G120ı
POWER MODULE PM250ı
WITH BUILT IN CL. A FILTERı
POSSIBILITY OF REGENERATIONı
3AC380-480V +10/-10% 47-63HZı
OUTPUT HIGH OVERLOAD: 75KWı
FOR 200% 3S,150% 57S,100% 240Sı
AMBIENT TEMP -10 TO +50 DEG Cı
OUTPUT LIGHT OVERLOAD: 90KWı
FOR 150% 3S,1