Description

Main function

– Product line: TeSys F
– Short name for the device: LR9F

Type of product or component

– Relays used: Motor protection
– Product compatibility: LC1F185 … LC1F400
– Network type: DC
– Thermal overload class: Class 10 conforms to IEC 60947-4 / Class 20 in accordance with IEC 60947-4
– Signaling function: Advance alarm indicator
– Adjustable heat protection area: 132 … 220 A
– Protection type: aM 250 Fuse A – for power circuit / BS 5 Fuse – for remote control / GB2 5 Circuit breaker – for remote control / gG 315 Fuse – for power circuit / gG 5 Fuse lead – for remote control

Additional features

– Network frequency: 50/60 Hz
– Supply voltage: 24 V DC
– Supply voltage limit: 17 … 32 V
– Mounting support: Directly on the contactor / Railway
– Activation threshold: 1.05 +/- 0.06 inch alarm complies with IEC 60947-4-1 / 1.12 +/- 0.06 when activated in compliance with IEC 60947-4-1
– Resistance to shock waves: 4 kV in accordance with IEC 61000-4-5
– Rated operating voltage: 1000 V AC 50/60 Hz for power circuit according to VDE 0110 gr C
– Rated insulation voltage: 1000 V AC circuit conforming to IEC 60947-4
– Rated voltage impulse withstand voltage: 8 kV in accordance with IEC 60947-1
– Phase loss sensitivity: Activated in 4 seconds +/- 20% complies with IEC 60947-4-1
– Reset: Manual reset
– Temperature compensation: -20 … 70 ° C
– Power consumption: <= 5 mA without load
– Power conversion in mA: 0 … 150 mA
– Overload protection at output: Release automatically
– Output short circuit protection: Automatically released
– Waste voltage: 0 … 2.5 V close rate
– Height: 123.5 mm
– Width: 115mm
– Depth: 101 mm
– Product weight: 0.95 kg