Cable end & Junction box

SKU: 11-dau-cap-hop-noi Category:

Description

General introduction

– The cable end is an accessory of the power cable, which comes with the power cable, used for the purpose of restoring the damage of the cable. Mainly constructed of Silicone / EPDM rubber, fast construction by cold shrink / heat method. Widely used in the field of electrical construction, civil electricity and industry ..
– There are 2 types of cable ends (cold-rolled cable head and heat-shrinking cable).

I) Cable end of cable

For medium voltage cables armor or armor, power ap to 36kV. The cable end is made of fast-drying silicone rubber, designed to be suitable for all medium-voltage cables with metal screen structure, with or without armor, copper or aluminum conductor.

Scope of application

    • Used for medium voltage cables up to 36kV
    • For insulated cables: polyethylene, XLPE, EPR.
    • For 1, 3 core cables, copper or copper tape shielding, with or without armor.
    • Conductor made of copper or aluminum.
    • Installation for places with polluted environment, dust …
    • Used to connect to the switches, transformers, motors, busbars, overhead lines …

Specifications

    • Cable ends used for power cables with continuous operating temperature at 90oC and overload at 130oC.
    • The rated current of the cable end is equal to or exceeds the rated current of the cable used.
    • The cable end has a special high-K (High-K) integrated layer to control the electric field around the insulation under the cable end.
    • The electric field in the cable directly below the High-K layer will be smaller than the case without the High-K cable.

II) Table shrink cable

Used for medium voltage cable with price or without armor, voltage up to 40.5kV. Cable end made of Silicone / EPDM rubber, fast construction by cold shrink method, designed suitable for all medium voltage cables with metal screen structure, with or without armor, copper conductor or aluminum.

Scope of application

    • Used for medium voltage cables up to 40.5kV
    • For insulated cables: polyethylene, XLPE, EPDM
    • For 1, 3 core cables, copper or copper tape shielding, with or without armor.
    • Conductor made of copper or aluminum.
    • Installation for places with polluted environment, dirt ….
    • Used to connect to the switches, transformers, motors, busbars, overhead lines …

Specifications

    • Cable ends used for power cables with continuous operating temperature at 90oC and overload at 130oC.
    • The rated current of the cable end is equal to or exceeds the rated current of the cable used.
    • The cable end has a special high-K (High-K) integrated layer to control the electric field around the insulation under the cable end.
    • The electric field in the cable directly below the High-K layer will be smaller than the case without the High-K cable.